| | Small
ultrasound systems which meet the increasing expectations for concurrently diagnostic
confidence and highest productivity as well. User friendly operation extends ultrasound
diagnostics more efficient and accurate, with maximum cost-performance. These
multipurpose systems are supported by a wide-band probe family, for covering full
range of application requirements in Hospital Departments and smaller Private
Clinics. | | | | |
| | TECHNICAL
SPECIFICATION: | | | | |
| |
1. DISPLAY MODES - B, B+B, 4B, B+M, M, ZOOM
| |
| | |
| |
2. SCANNING MODES - electronic linear / convex / microconvex /
sector | | | | |
| |
3. FEATURES - image memory: 512 x
512 x 8 - gray scale: 256 levels - cineloop (256 frames/screen) - extended
/ elongated focusing zone - multifocus ( 4 foc. points) - scan depth: 2...25
cm - scanning rate: max. 25 frames / sec (automatically optimized) - 4 selectable
sweep speed in M-mode - 5 zones of TGC control for each of the scan depth -
image orientation: L/R, Up/Dn, Pos/Neg - Tissue Harmonic Visualization THV -
image processing: - adaptive correlation: 4 steps -
postprocessing: 5 steps - edge enhanced processing - image annotation:
alphanumeric, comments, patient information, date, time, bodymarks -
probe interface: - 2 electronic - option: 1 for
special probes - Hi-Res. 15" LCD monitor - magnification function / ZOOM -
large, versatile trackball - independent report pages: B, M, OB/GYN - Help
function - applications presets - adjustable keyboard (height, swivel) -
adjustable monitor (height, swivel, tilt)
| |
| | |
| |
4. OPTIONAL EQUIPMENT
- videoprinter
B/W

- biopsy
attachments
- non-volatile Image Memory (up to 2000 images)
 - USB-Pen
Memory Module up to 2000 images capacity (transfer images to
PC using USB Pen Drive) 
| | | | |
| |
5. MEASUREMENTS B-Mode: - distance
(4 pair of cursors) - area, circumference (ellipse) - volume (ellipsoid,
3 axis method) - angles - urology calculations and others according to order
Ob/Gyn
calculation programs: - BPD, CRL, FL, GS, AC, HC, NT, NB, YS (factory & user
table) - fetus weight FW (AC/BPD) - ratio calculations: FL/BPD, HC/AC -
GA mean automatic calculation of birth date EDD
M-Mode: - calculations
of time, velocity, amplitude, heart rate - cardiac measurements: EDV, ESV,
CO, SV, EF - fast measurements of AOD, LA, RVED, DE_Amp, IVS | |
| | |
| |
6. OUTPUTS TV PAL system for connection:
- auxiliary B/W monitor - B/W videoprinter - VGA video | |
| | |
| |
7. MULTI-FREQUENCY PROBE TYPES: Electronic multi-frequency probe
types (2,5~12MHz): - convex:
CA-255 /R60 (2,5~5,0 MHz)  -
linear: LA-510 /L40 (5,0~10,0 MHz) 
- microconvex
endovaginal: CV-580/R13 (5~8 MHz)
-
convex: CA-409/ R13 (4,0~9,0 MHz)  -
convex: CA-305/ R20 (2,5~6,0 MHz) 
- Special
Probes | |
| | |
| |
8. POWER SUPPLY - Power supply: AC
100/240 V, 50/60 Hz - Power consumption: 40 VA | |
| | |
| |
9. DIMENSIONS AND WEIGHT - 500 x 570 x 1300, 18 kg (with monitor
+ trolley) | | | | |
|
ECHO-SON reserves the right to change design and specification