Desmin H
Back  
 Small, portable ultrasound systems which meet the increasing expectations for concurrently diagnostic confidence and highest productivity as well. User friendly operation extends ultrasound diagnostics more efficient and accurate, with maximum cost-performance. These multipurpose systems are supported by a wide-band probe family, for covering full range of application requirements in Hospital Departments and smaller Private Clinics. 
 TECHNICAL SPECIFICATION:
 
 
1. DISPLAY MODES

- B, B+B, 4B,B+Zoom, Zoom, M, B+M
 
 
2. SCANNING MODES


- electronic linear / convex / micro-convex
- mechanical convex / sector, micro-convex
 
 


3. FEATURES


- DSP - digital signal processing and digitally controlled
- portable general purpose diagnostic ultrasound system
- probe interface: 1x electonic (option) i 2x mechanical
- image memory: 512 x 512 x 8
- gray scale: 256 levels
- cineloop (256 frames)
- focusing: extended / elongated zone
- multi (4 foc. points)
- scan depth: 3-25 cm
- scanning rate: max. 25 frames / sec (automatic optimum setting )
- 4 selectable sweep speed in M-mode
- 3 zones of TGC control for each of thescan depth
- image orientation: L/R, Up/Dn, Pos/Neg
- image processing:
  - adaptive correlation: 4 steps
  - postprocessing: 4 steps
- edge enhanced processing
- display information: Patient ID, date, time, name, comments /
  annotation
- Hi-Res. non interlaced 9" CRT monitor ( LCD: 10,4" -option )
- zoom 6 steps
- large, versatile trackball
- all results of the measurements are stored on the independent
  report pages
- alphanumerical keyboard

 
 
4. OPTIONAL EQUIPMENT


- trolley
- bag
- videoprinter B/W
  

- biopsy attachments
- non-volatile Image Memory (up to 1000 images)
- USB-Pen Memory Module up to 2000 images capacity
  (transfer images to PC using USB Pen Drive)

 
 
5. MEASUREMENTS


B-Mode:
- distance (4 pair of cursors)
- area, circumference (ellipse)
- volume (ellipsoid, 3 axis method)

Prenatal calculation programs:
- BPD, CRL, FL, GS, AC, HC(factory & user table)
- fetus weight FW (AC/BPD)
- ratio calculations: FL/BPD, HC/AC
- GA mean
- automatic calculation of birth date EDD

M-Mode:
- calculations of time, velocity, amplitude,heart rate
- cardiac measurements: EDV, ESV, CO,SV, EF
- fast measurements of AOD, LA, RVED,DE_Amp, IVS, PW
 
 
6.
OUTPUTS

TV PAL for connection:
- auxiliary B/W monitor
- B/W videoprinter
- frame grabber PC cards
 
 
Electronic:
- convex: CA-255 /R60 (2,5~5,0 MHz)
- convex: CA-305/ R20 (2,5~6,0 MHz)
- convex: CA-409/ R13 (4,0~9,0 MHz)

- linear: LA-510 /L40 (5,0~10,0 MHz)

- micro-convex endovaginal: CV-580/R13 (5~8 MHz)



Special Probes
 
 
8. POWER SUPPLY

Power supply: AC 100/240 V, 50/60 Hz
Power consumption: 40 VA
 
 
9. DIMENSIONS AND WEIGHT

- 335 x 560 x 280 ca. 10 - 13 kg (*)
- trolley: 465 x 512 x 775ca. 8.2 kg


(*) depends on configuration
 

ECHO-SON reserves the right to change design and specification without notice. All rights reserved.
 
Back  
 © ECHO-SON S.A., 24-100 Pulawy, ul. Krancowa 5, POLAND tel. +48 81 886 3613, fax +48 81 886 8310, export@echoson.com.pl