| | Small,
portable ultrasound systems which meet the increasing expectations for concurrently
diagnostic confidence and highest productivity as well. User friendly operation
extends ultrasound diagnostics more efficient and accurate, with maximum cost-performance.
These multipurpose systems are supported by a wide-band probe family, for covering
full range of application requirements in Hospital Departments and smaller Private
Clinics. | | | | |
| | TECHNICAL
SPECIFICATION: | |
| | |
| |
FEATURES
- portable, general purpose diagnostic ultrasound system
- display modes:
- B, B+B, 4B, B+M, M, ZOOM
- scanning method:
- electronic linear / convex / microconvex /
sector
- image memory: 512 x 512 x 8
- gray scale: 256 levels
- cineloop (256 frames/screen)
- extended / elongated focusing zone
- multifocus ( 4 foc. points)
- scan depth: 2...25 cm
- scanning rate: max. 25 frames / sec (automatically optimized)
- 4 selectable sweep speed in M-mode
- 5 zones of TGC control for each of the scan depth
- image orientation: L/R, Up/Dn, Pos/Neg
- Tissue Harmonic Visualization THV
- image processing:
- adaptive correlation: 4 steps
- postprocessing: 4 steps
- edge enhanced processing
- image annotation: alphanumeric, comments, patient information,
date, time, bodymarks
- probe interface:
- 1 electronic
- option: 1 for special probes
- Hi-Res. 12'' LCD monitor
- magnification function / ZOOM
- large, versatile trackball
- independent report pages: B, M, OB/GYN
- Help function
- applications presets
| |
| | |
| |
MEASUREMENT FUNCTIONS
B-Mode:
- distance (4 pair of cursors)
- area, circumference (ellipse)
- volume (ellipsoid, 3 axis method)
- angles
- urology calculations and others according to order
Ob/Gyn calculation programs:
- BPD, CRL, FL, GS, AC, HC, NT, NB, YS (factory & user table)
- fetus weight FW (AC/BPD)
- ratio calculations: FL/BPD, HC/AC
- GA mean automatic calculation of birth date EDD
M-Mode:
- calculations of time, velocity, amplitude, heart rate
- cardiac measurements: EDV, ESV, CO, SV, EF
- fast measurements of AOD, LA, RVED, DE_Amp, IVS, |
| | | |
| |
4. OPTIONAL EQUIPMENT
- videoprinter
B/W

- biopsy
attachments
- non-volatile Image Memory (IM),
up to 1000 images 
- USB-port for Pen Memory Module (PM)
up to 2000 images
capacity (transfer images to PC using USB port and
Pen
Drive) 
- trolley
- batter supply (option)
|
|
| | |
| |
6. OUTPUTS
TV PAL system for connection:
- auxiliary B/W monitor
- B/W videoprinter |
|
| | |
| |
Electronic:
- convex:
CA-255 /R60 (2,5~5,0 MHz) 
- linear: LA-510 /L40 (5,0~10,0
MHz)
- micro-convex endovaginal: CV-580/R13
(5~8 MHz) 
- convex: CA-305/ R20 (2,5~6,0
MHz) 
- convex: CA-409/ R13 (4,0~9,0
MHz) 
- Special Probes
|
| | | |
| |
8. POWER SUPPLY Power supply: AC 100/240 V, 50/60 Hz Power
consumption: 40 VA | | | | |
| |
9. DIMENSIONS AND WEIGHT
- 310 x 155 x 290 / 6 kg
|
|
| | |
|
ECHO-SON reserves the right to change design and specification
without notice. All rights reserved. | |
| | |
|