| | Small,
portable ultrasound systems which meet the increasing expectations for concurrently
diagnostic confidence and highest productivity as well. User friendly operation
extends ultrasound diagnostics more efficient and accurate, with maximum cost-performance.
These multipurpose systems are supported by a wide-band probe family, for covering
full range of application requirements in Hospital Departments and smaller Private
Clinics. | | | | |
| | TECHNICAL
SPECIFICATION: | | | | |
| |
1. DISPLAY MODES - B, B+B, 4B,B+Zoom, Zoom, M, B+M - Option:
PW (Pulse Wave Doppler) - Option: Color Doppler: CF (Color Flow, PF (Power
Flow ), B+CF/PF+PW | |
| | |
| |
2. SCANNING MODES - electronic linear / convex / micro-convex
| | | | |
| |
3. FEATURES -
color Doppler module (option) 
- DSP - digital signal processing and digitally controlled - SAS - Spectral
Adaptive System - THV - Tissue Harmonic Visualization - ESR - Enhanced
Speckles Reduction - Dynamic aperture, apodization & mix-dynamic focusing
- 5 zones of TGC control for each of the scan depth - Gray scale 256 -
Image memory 512 x 512 x 8 - Display: Hi-Res non-interlaced 10" LCD monitor -
Scanning frame rate up to 25 fps (automatically optimized) - M-mode sweep
speed: selectable from about 2 to 9 sec/screen - Zoom 6 steps - Scanning
depth range: from 2 cm to 25 cm - Image orientation: L/R, Up/Dn, Pos./Neg.
- Cineloop memory (256-frames/screens) - Digital filters - adaptive correlation,
edge enhancement, wall filter, reject - Gray scale postprocessing
- Image annotation: alphanumeric, comments, patient information, date,
time, body marks - Large, versatile trackball - Independent report pages:
B, M, PW, OB/GYN - Probe interface: 1-2 electronical (+ 2 for special probes)
- Easy upgrade and customize to specific diagnostic requirements
| |
| | |
| |
4. OPTIONAL EQUIPMENT - videoprinter
B/W

-
videoprinter
color

- biopsy
attachments
- non-volatile Image Memory (up to 1000 images)
 - USB-Pen
Memory Module up to 2000 images capacity (transfer images to
PC using USB Pen Drive) 
| | | | |
| |
5. MEASUREMENTS
B-mode: - Distance (4 pairs of cursors) - Area, circumference (ellipse,
contour) - Volume (ellipsoid, contour, 3-axis method) - Urology calculations
and others according to order Prenatal
calculation programs: - BPD, CRL, FL, GS, AC, HC (factory & user table)
- fetal weight FW [AC/BPD] - ratios calculation FL/BPD, HC/AC , FL/AC
- GA mean (automatic averaging of fetal age) - automatic calculation of the
date of birth EDD - user and manufacturer table M-mode:
- multi-measurement possibility - time, velocity, amplitude (t, v, d)
- Heart rate (HR) - LV measurement calculation: EDV, ESV, CO, SV, EF -
fast measurements of: AOD, LA , RVED, DE_Amp, IVS Doppler PW: - time,
speed, acceleration (t, v, a) - PHT, MVA, max. PG, mean PG, HR - vessel
index: A/B, RI, PI
| |
| | |
| |
6. OUTPUTS TV PAL for connection:
- auxiliary B/W monitor - B/W videoprinter - frame grabber PC cards | |
| | |
| |
7. MULTI-FREQUENCY TRANSDUCER TYPES: Electronic: -
convex: CA-255 /R60 (2,5~5,0 MHz) 
- convex: CA-305/ R20 (2,5~6,0 MHz) 
- convex: CA-409/ R13 (4,0~9,0 MHz) 
- linear: LA-510 /L40 (5,0~10,0
MHz)
- micro-convex endovaginal: CV-580/R13 (5~8 MHz)

- Special Probes
| | | | |
| |
8. POWER SUPPLY Power supply: AC 100/240 V, 50/60 Hz Power
consumption: 40 VA | | | | |
| |
9. DIMENSIONS AND WEIGHT - 330 x 370 x 270mm; 8 kg* - trolley:
465 x 512 x 775 ca. 8.2 kg (*) depends on configuration | |
| | |
|
ECHO-SON reserves the right to change design and specification
without notice. All rights reserved. | |
| | |
|