| | Designed
for e.g. Private Clinics, Smaller Hospitals, Emergency Departments, First Aid
Units, Intensive Care Units etc. Its main application focus is in Abdominal, OB/GYN
and Vascular Imaging. Powerful Color and Spectral Doppler technology, high quality
and high resolution of tissue visualization provide maximum productivity and diagnostic
accuracy. | | | | |
| | TECHNICAL
SPECIFICATION: | | | | |
| |
1. DISPLAY MODES: - B, B+B, 4B,B+Zoom, Zoom, M, B+M - Option:
PW (Pulse Wave Doppler) - Option: Color Doppler: CF (Color Flow, PF (Power
Flow ), B+CF/PF+PW | |
| | |
| |
2. SCANNING MODES: - electronic linear / convex /micro-convex
- mechanical convex / sector, micro-convex | |
| | |
| |
3. FEATURES: - Doppler module 
- Multi-frequency system ( auto - optimized
) - Dynamic aperture, apodization & mix-dynamic focusing - Tissue Harmonic
Visualization (THV) - 5 zones of TGC control for each of the scan depth
- Gray scale 256shades of gray, image memory 512 x 512 x 8 - Display : Hi-Res
non- interlaced 12~15" LCD monitor - Scanning frame rate up to 25Hz (automatically
optimized) - M-mode sweep speed: selectable from about 2 to 9 sec/screen
- Zoom 6 steps
- Scanning depth range: from 2 cm to 25 cm - Image orientation : L/R, Up/Dn,
Pos./Neg. - Cineloop memory (256-frame) - Digital filters - adaptive
Correlation , Edge Enhancement, Wall filter, Reject - Gray scale
postprocessing - Image annotation: alphanumeric, comments, patient information,
date, time, body marks - Large, versatile trackball - Independent
report pages : B, M, PW, OB/GYN - Probe interface: 1x electronic ( and 1
mechanical -option) - Easy upgrade and customize to specific diagnostic requirements
| | | | |
| |
4. OPTIONAL EQUIPMENT: - videoprinter
( B/W or color)
- biopsy
attachments
- Internal non-volatile memory module up to 1000
images capacity 
- USB-Pen Memory Module up to 2000 images capacity
(transfer images to PC using USB Pen Drive) 
- Internal or car battery supply | |
| | |
| |
5. MEASUREMENTS: B-mode : -
Distance (4 pair of cursors) - Area, circumference (ellipse, contour)
- Volume (ellipsoid, contour, 3-axis method) - Urology calculations and others
according to order Prenatal calculation programs: - BPD, CRL, FL,
GS, AC, HC (factory & user table) - fetal weight FW [AC/BPD] - ratios
calculation FL/BPD, HC/AC , FL/AC - GA mean (automatic averaging of fetal
age) - automatic calculation of the date of birth EDD - user and manufacturer
table M-mode: - multi-measurement possibility - time, velocity,
amplitude (t, v, d) - Heart rate (HR) - LV measurement calculation:
EDV, ESV, CO, SV, EF - fast measurements of: AOD, LA, RVED, DE_Amp, IVS
Doppler PW: - time, speed, acceleration (t, v, a) - PHT, MVA, max.
PG, mean PG, HR - vessel index : A/B, RI, PI | |
| | |
| |
6. MULTI-FREQUENCY TRANSDUCER TYPES:
Electronic: - convex:
CA-255 /R60 (2,5~5,0 MHz) 
- convex: CA-305/ R20 (2,5~6,0 MHz) 
- convex: CA-409/ R13 (4,0~9,0 MHz) 
- linear: LA-575 /L64 (5,0~7,5 MHz) 
- linear: LA-510 /L40 (5,0~10,0 MHz) 
- linear: LA-912 /L30 (9,0~12 MHz) 
- micro-convex endovaginal: CV-580/R13 (5~8 MHz)

- Special Probes
| | | | |
| |
7. POWER SUPPLY: - Power supply:
AC 100/240 V, 50/60 Hz - Power consumption: 40 VA | |
| | |
| |
8. DIMENSIONS AND WEIGHT: - 412 mm x 440 mm x 350 mm; 8,7 kg (including
15'' LCD monitor)* - trolley: 465 x 512 x 775 ca. 8.2 kg * - depends
on configuration | | | | |
|
ECHO-SON reserves the right to change design and specification
without notice. All rights reserved. | |
| | |
|