| | Modular
architecture and flexible configurations designate SPINEL II, for being able to
be programmed and customized for specific diagnostic requirements. Powerful Color,
Power and Spectral Doppler technology, high quality and high resolution of tissue
visualization provide maximum productivity and diagnostic accuracy. This ahead-proof
solutions make it a solid investment in a long time for the future. | |
| | |
| | TECHNICAL
SPECIFICATION: | | | | |
| |
1. DISPLAY MODES: - B, B+B, 4B,B+Zoom, Zoom, M, B+M - Option:
PW (Pulse Wave Doppler) - Option: Color Doppler: CF (Color Flow), PF (Power
Flow ), B+CF/PF+PW | |
| | |
| |
2. SCANNING MODES: - electronic linear / convex /micro-convex
| | | | |
| |
3. FEATURES: - color Doppler module
-
DSP - digital signal processing and digitally controlled - Multi-frequency
system (auto-optimized) - Dynamic aperture, apodization & mix-dynamic focusing
- Tissue Harmonic Visualization (THV) - 5 zones of TGC control for each of
the scan depth - Gray scale 256 - Image memory 512 x 512 x 8 bits
- Display: Hi-Res non- interlaced 15" LCD monitor (12'' - 17''-option) -
Scanning frame rate up to 25 fps (automatically optimized) - M-mode sweep
speed: selectable from about 2 to 9 sec/screen - Zoom
6 steps - Scanning depth range: from 2 cm to 25 cm - Image
orientation: L/R, Up/Dn, Pos./Neg. - Cineloop memory (256-frames/screens)
- Digital filters - adaptive correlation, edge enhancement, wall filter,
reject - Gray scale postprocessing - Image annotation: alphanumeric,
comments, patient information, date, time, body marks - Large,
versatile trackball - Independent report pages: B, M, PW, OB/GYN - Probe
interface: 1-2 electronical (+ 2 for special probes)
- Easy upgrade and customize to specific diagnostic requirements | |
| | |
| |
4. OPTIONAL EQUIPMENT: -
videoprinter
B/W

-
videoprinter
color

- biopsy
attachments
- Internal non-volatile memory module up to 1000
images capacity 
- USB-Pen Memory Module up to 2000 images capacity
(transfer images to PC using USB Pen Drive) 
| | | | |
| |
5. MEASUREMENTS: B-mode : - Distance
(4 pair of cursors) - Area, circumference (ellipse, contour) - Volume
(ellipsoid, contour, 3-axis method) - Urology calculations and others according
to order Prenatal calculation programs: - BPD, CRL, FL, GS, AC, HC
(factory & user table) - fetal weight FW [AC/BPD] - ratios calculation
FL/BPD, HC/AC , FL/AC - GA mean (automatic averaging of fetal age) - automatic
calculation of the date of birth EDD - user and manufacturer table
M-mode: - multi-measurement possibility - time, velocity, amplitude (t,
v, d) - Heart rate (HR) - LV measurement calculation: EDV, ESV, CO, SV,
EF - fast measurements of: AOD, LA, RVED, DE_Amp, IVS Doppler PW:
- time, speed, acceleration (t, v, a) - PHT, MVA, max. PG, mean PG, HR
- vessel index : A/B, RI, PI
| | | | |
| |
6. MULTI-FREQUENCY TRANSDUCER TYPES: Electronic: -
convex: CA-255 /R60 (2,5~5,0 MHz) 
- convex: CA-305/ R20 (2,5~6,0 MHz) 
- convex: CA-409/ R13 (4,0~9,0 MHz) 
- linear: LA-510 /L40 (5,0~10,0
MHz)
- micro-convex endovaginal: CV-580/R13 (5~8 MHz)

- Special Probes
| | | | |
| |
7. POWER SUPPLY: - Power supply:
AC 100/240 V, 50/60 Hz - Power consumption: 60 VA | |
| | |
| |
8. DIMENSIONS AND WEIGHT: -
440 x 590 x 140 mm; 9 kg* (without monitor & trolley) - 620 x 740 x 1240 mm
(with monitor & trolley) - 35 kg* (including 15'' LCD monitor)
* - depends on configuration
| |
| | |
|
ECHO-SON reserves the right to change design and specification
without notice. All rights reserved. | |
| | |
|